Adsorption and Porosity
-
Autosorb 6100 | Anton Paar QuantaTec
Manometric adsorption analyzer gas adsorption isotherms from turbomolecular pump vacuum up to 1 bar of gases such as nitrogen, argon, krypton, carbon dioxide and hydrogen. Determination of adsorption properties, surface area, pore volume, pore size / pore size distribution, pore network characteristics of adsorbents. -
Poremaster | Anton Paar QuantaTec
Mercury porosimeter for the measurement of mercury intrusion and extrusion curves of porous materials in a pressure range from vacuum up to 60,000 psi. Determination of pore size and volume distributions of meso and macroporous materials with pores of approx. 5 nm up to 400 µm -
Ultrapyc 5000 | Anton Paar Quantatec
Helium pycnometer for the determination of the skeletal density. Volumes in the range of 4.5 up to 135 cm3 can be measured. The temperature can be controlled between 15 and 50°C. -
Minispec mq20 | Bruker
Benchtop time-domain 1H nuclear magnetic resonance (NMR) relaxometry device (frequency 20 MHz) for determination of the spin-lattice (T1) and spin-spin (T2) relaxation time of liquids in contact to porous materials and powders. Information about liquid saturation, wettability, wetted surface area and pore size of adsorbents. -
Acorn Area | Xigo Nanotools
Benchtop time-domain 1H nuclear magnetic resonance (NMR) relaxometry device (frequency: 13 MHz) for determination of the spin-lattice (T1) and spin-spin (T2) relaxation time of liquids in contact to porous materials and powders. Information about liquid saturation, wettability, wetted surface area and pore size of adsorbents. -
Magnetic Suspension Balance | Rubotherm
High-resolution high-pressure adsorption isotherms up to 130 bar to study the adsorption behavior/capacity of gases such as methane and carbon dioxide on porous adsorbents, temperatures: 15 – 150 °C.
Chromatography
-
High-Performance Liquid Chromatography -
Merck HITACHI LaChrom
Chromatographic setup for Inverse Size Exclusion Chromatography based on the measurement of standards such as pullulan (in water) or polystyrene (in THF) with known sizes. Information about the pore size of the nanoporous material packed inside of the chromatographic column.
Centrifugation Techniques
-
LUMiSizer
Dispersion analyzer for the determination of particle size distribution, stability analysis and more.
-
Optima
Analytical ultracentrifugation is one of the most versatile and accurate methods for characterizing proteins, macromolecules, nanoparticles and other heterogeneous mixtures.
-
DC24000
Disc centrifugation is a proven sedimentation-based method for accurate, high-resolution particle size measurement.
Diffraction Techniques
-
Empyrean (XRD)
Light Scattering
-
DLS Nano ZS ZEN 3600 -
Goniometer CGS-3 -
LUMiSpoc -
Mastersizer 3000 -
NanoSight Pro -
SMPS TSI 3776
Microscopy
-
Atomic Force Microscopy -
Confocal Microscopy -
Optical Microscopy -
Raman Microscopy -
Scanning Electron Microscopy
Rheology
-
Discovery HR-2 | Waters -
MCR 302 | Anton Paar -
RST-XS.s | Dr. Dietmar Schulze
Surface and Interface
-
Inverse Gas Chromatography -
Particle Charge Detector -
Quarz Crystal Microbalance -
Tensiometry
Thermal Analysis
-
Dynamic Differential Calorimetry -
Isothermal Titration Calorimetry -
Thermogravimetric Analysis