• Skip navigation
  • Skip to navigation
  • Skip to the bottom
Simulate organization breadcrumb open Simulate organization breadcrumb close
Interdisciplinary Center for Functional Particle Systems
  • FAUTo the central FAU website
  1. Friedrich-Alexander-Universität
  2. FAU Forschungszentren
Suche öffnen
  • Campo
  • StudOn
  • FAUdir
  • Jobs
  • Map
  • Help
  1. Friedrich-Alexander-Universität
  2. FAU Forschungszentren

Interdisciplinary Center for Functional Particle Systems

Navigation Navigation close
  • Research
  • People
  • About FPS
    • Participating Institutions
    • Structure
    Portal About FPS
  • Contact
  1. Home
  2. Core Facility
  3. Facilities
  4. Unit Vogel: Particle size, shape and composition
  5. X-Ray Diffractometry

X-Ray Diffractometry

In page navigation: Core Facility
  • Structure
  • Facilities
    • Unit Vogel: Particle size, shape and composition
      • Analytical Centrifugation
      • Analytical Ultracentrifugation
      • Atomic Force Microscopy
      • Confocal Microscopy
      • Differential Scanning Calorimetry
      • Disc Centrifugation
      • Dynamic Image Analysis
      • Dynamic Light Scattering
      • Fluorescence Spectroscopy
      • ICP-OES
      • Impedance Spectroscopy
      • Inverse Gas Chromatography
      • Isothermal Titration Calorimetry
      • Laser Diffraction Analysis
      • Nanoparticle Tracking Analysis
      • Optical Microscopy
      • Particle Charge Detection
      • Quarz Crystal Microbalance
      • Raman Microscopy
      • Scanning Electron Microscopy
      • Scanning Mobility Particle Sizer
      • Single Particle Analysis
      • Tensiometry
      • Thermogravimetric Analysis
      • UV/Vis/NIR Spectroscopy
      • X-Ray Diffractometry
    • Unit Hartmann: Spectroscopy of functional particle surfaces
    • Unit Thommes: Texture and adsorption properties of porous systems
  • User Access

X-Ray Diffractometry

X-Ray Diffractometer | PANalytical, Empyrean with Anton Paar Cryo & Humidity Chamber (CHC plus+) and Low-Temperature Chamber (TTK 600)

Location: LFG, Haberstraße 9a, 91058 Erlangen, Room U1.825

An X-ray diffractometer is an instrument used to study the structure of crystalline phases in materials. X-ray diffraction takes place in the sample and the diffraction angles and intensities are measured.

M. Sc. Matthias Kawalek

The XRD Empyrean Series 2 diffractometer (Bragg-Brentano geometry) is equipped with a Cu-alpha X-ray tube and a PIXcel3D detector. Several sample holders are available for measurements:

  • Reflection-transmission spinner:
    o Membrane holder
    o Powder sample holder
  • Sample holder for planar substrates (reflection)
  • Anton Paar TTK 600:
    o Powder measurement (static)
    o Nitrogen cooling for low temperature measurements
    o Temperature range
    -193 °C to 450 °C with vacuum
    -193 °C to 300 °C without vacuum
  • Anton Paar CHC plus+ humidity chamber
    o Powder measurement (static)
    o Air cooling: temperature range -5 °C to 300 °C
    o Relative humidity from 5% to 95%

https://www.malvernpanalytical.com/en/products/product-range/empyrean-range/empyrean