• Skip navigation
  • Skip to navigation
  • Skip to the bottom
Simulate organization breadcrumb open Simulate organization breadcrumb close
Interdisciplinary Center for Functional Particle Systems
  • FAUTo the central FAU website
  1. Friedrich-Alexander-Universität
  2. FAU Forschungszentren
Suche öffnen
  • Campo
  • StudOn
  • FAUdir
  • Jobs
  • Map
  • Help
  1. Friedrich-Alexander-Universität
  2. FAU Forschungszentren

Interdisciplinary Center for Functional Particle Systems

Navigation Navigation close
  • Research
  • People
  • About FPS
    • Participating Institutions
    • Structure
    Portal About FPS
  • Contact
  1. Home
  2. Core Facility
  3. Facilities
  4. Unit Vogel: Particle size, shape and composition
  5. Fluorescence Spectroscopy

Fluorescence Spectroscopy

In page navigation: Core Facility
  • Structure
  • Facilities
    • Unit Vogel: Particle size, shape and composition
      • Analytical Centrifugation
      • Analytical Ultracentrifugation
      • Atomic Force Microscopy
      • Confocal Microscopy
      • Differential Scanning Calorimetry
      • Disc Centrifugation
      • Dynamic Image Analysis
      • Dynamic Light Scattering
      • Fluorescence Spectroscopy
      • ICP-OES
      • Impedance Spectroscopy
      • Inverse Gas Chromatography
      • Isothermal Titration Calorimetry
      • Laser Diffraction Analysis
      • Nanoparticle Tracking Analysis
      • Optical Microscopy
      • Particle Charge Detection
      • Quarz Crystal Microbalance
      • Raman Microscopy
      • Scanning Electron Microscopy
      • Scanning Mobility Particle Sizer
      • Single Particle Analysis
      • Tensiometry
      • Thermogravimetric Analysis
      • UV/Vis/NIR Spectroscopy
      • X-Ray Diffractometry
    • Unit Hartmann: Spectroscopy of functional particle surfaces
    • Unit Thommes: Texture and adsorption properties of porous systems
  • User Access

Fluorescence Spectroscopy

Photoluminescence Spectrometer | Horiba, FluoroLog-3

Location: LFG, Haberstraße 9a, 91058 Erlangen, Room 01.814

The basic configuration of this photoluminescence spectrometer consists of monochromators with gratings in the excitation and emission positions and a red sensitive photomultiplier. Intensity correction up to 850 nm is available as an option. The instrument offers excellent sensitivity and performance for a wide range of experimental requirements.

M. Sc. Hadi Soltanmoradi

  • Applicable sample holders: standard, micro, flow-through, fixed sample holder
  • Light/radiation source: 450W Xenon lamp
  • Excitation wavelength range: 200 to 2000 nm
  • Emission wavelength range: 200 to 950 nm
  • Monochromator type: modular, Czerny-Turner, single or double monochromator, iHR320 or iHR550 spectrograph for multi-channel detection
  • Accuracy/reproducibility of settings: ±0.5 nm accuracy, ±0.1 nm reproducibility
  • Temperature control: room temperature

https://www.horiba.com/fileadmin/uploads/Scientific/Downloads/UserArea/Fluorescence/Manuals/Total_Fluorolog-3_Manual_J81014_rev_G__May_2014_.pdf

Further information to follow